It’s Friday and time for the 13th Tech tip! Today we are going to go over some simple parameter sheet tricks and best practices. Parameter sheets are incredibly useful for running many different design or operation analyses. Let’s go over how best to utilize their functionality. In this example we’re working in Flownex version 8.12.7.4334

Parameter Sheet Setup

Probably the most critical thing to know when working with Parameter Sheets in Flownex is to make our edits through the setup interface. This is where we define the connection between Flownex and the worksheet.

1 parameter table setup

As we recall, adding either inputs or results to our parameter sheet is as simple as dragging and dropping them into the different columns.

Renaming Parameter Columns

We may find that we’d like a more descriptive name of an input or result parameter than simply
“Pressure” or “Temperature”. We can rename the columns and this must be done via the parameter table setup. If we were to change the name in the worksheet it will be overwritten by the setup when the model is solved.

2 rename parameters

Rearranging Parameters

We may decide after creating a parameter table that we need to go back in and add a new column between existing input or result parameters. This should be done, again, through the setup. We will add our new parameter to the first open column and then move it within the setup.

3 rearrange columns

*Important Note: Cell references in Excel are explicit in parameter sheets. If we are performing calculations in the parameter sheet using cell references and we rearrange columns these formulas will need to be updated.

Bonus Tip!

Categories

Get Your Ansys Products & Support from the Engineers who Contribute to this Blog.

Technical Expertise to Enable your Additive Manufacturing Success.

PADT’s Pulse Newsletter

Keep up to date on what is going on at PADT by subscribing to our newsletter.


By submitting this form, you are consenting to receive marketing emails from: . You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact

Share this post:

Upcoming Events

04/24/2024

Experience Stratasys Truck Tour: Houston, TX

05/07/2024

Experience Stratasys Truck Tour: Albuquerque, NM

05/07/2024

Dynamic Simulation for Rocket Propellant Systems! - Webinar

05/08/2024

Fluent Materials Processing Updates in Ansys 2024 R1 - Webinar

05/13/2024

Experience Stratasys Truck Tour: Tempe, AZ

05/14/2024

Simulation World 2024

05/15/2024

Simulation World 2024

05/16/2024

Simulation World 2024

05/22/2024

Optics Updates in Ansys 2024 R1 - Webinar

06/12/2024

Connect Updates in Ansys 2024 R1 - Webinar

06/26/2024

Structures Updates in Ansys 2024 R1 (3) - Webinar

06/27/2024

E-Mobility and Clean Energy Summit

07/10/2024

Fluids Updates in Ansys 2024 R1 - Webinar

08/05/2024

2024 CEO Leadership Retreat

10/23/2024

PADT30 | Nerdtoberfest 2024

Search in PADT site

Contact Us

Most of our customers receive their support over the phone or via email. Customers who are close by can also set up a face-to-face appointment with one of our engineers.

For most locations, simply contact us: